CONSULTING
KOLDWORKS
Electromagnetic Fields
Radiated
Frequency Interference
High
Frequency Interference
Grounding Studies & Enhancement
Ground Resistant Testing
Signal Reference Grounding
Power Quality Monitoring
Load Balance
Measurements
Energy Studies
Air-Conditioning & Flow
Analysis
Cooling System Evaluation
|

Increase Data
Center Reliability by Optimizing Your Existing Cooling
Infrastructure
KoldWorks is a suite of specialized engineering and educational
services designed by Upsite Technologies® to enhance data center
performance without additional capital investment.
> Boost data center reliability
> Optimize your current cooling infrastructure
> Enable precision cooling to reduce or eliminate hotspots
> Dramatically reduce bypass airflow
> Assist with data center ASHRAE compliance
> Learn the dynamics of your data center, including cooling
requirements, deficiencies,
and the science behind efficient operation
Comprehensive Diagnostic and Remediation Computer Room Services
As data center
rack densities increase and thermal loads rise, many organizations
resort to increasing the number of cooling units. While this may
appear to solve the problem, the added cooling capacity does not
offer precision cooling, which will help curb costs and improve
energy efficiency.
To achieve cooling efficiency and optimize your capacity, you must
eliminate the loss
of chilled air through unsealed cable openings, as well as examine
other data center
performance factors, including the location of perforated tiles,
relative humidity,
underfloor plenum airflow, computer-room layout, set points and
power consumption.
With a range of services, you will be able to meet your technical
and budgetary requirements.

Inadequate supply air volume
creates an environment in which equipment at the top
of cabinets is significantly hotter. In this photograph,
recirculation is evident over
the top of the cabinet, around the ends of rows, and within the
cabinet itself.
KOLDPROFILE
Upsite KoldProfile, one of the KoldWorks suite of service offerings,
is a survey of your data center cooling to determine the three
measurements of data center cooling health based on published
standards from ASHRAE and the
Uptime Institute:
> Data Center Hotspots—Temperature and Relative Humidity
> Bypass Airflow—To regain lost conditioned airflow
> Cooling Margin Available—To cool additional equipment
This service takes approximately 1-2 hours depending on data center
size and includes the following
activities:
> Count & size raised floor openings to estimate the percentage of
bypass airflow
> Measure cabinet air intake temperatures to determine the presence
of hotspots
> Measure relative humidity of any identified hotspots
> Sum cooling unit rated cooling capacity and convert from tons to
kilo watts (kW)
> Sum cooling unit rated airflow in CFM (cubic feet per minute)
> Sum computing equipment power load in kW
> Determine the presence of latent cooling and its associated Latent
Cooling Penalty
After the survey on the data center floor, you will receive:
> On site verbal discussion of findings and recommendations
> Written KoldProfile report detailing findings and recommendations
KoldProfile is necessary for data centers dedicated to improving IT
equipment reliability and optimizing critical physical
infrastructure. Learn how capital costs associated with installing
additional cooling equipment and operating costs can bereduced, and
determine redundant cooling capacity for a high heat density
computing equipment installation.
KOLDCHECK
Diagnose Key Data Center Conditions
Examine your data center infrastructure and find out how to regain
control of the cooling environment with KoldCheck diagnostic
services. Based on what you require, KoldCheck data center experts
benchmark your existing conditions and evaluate your computer room
to determine ways to optimize your existing cooling investment.
Upon completion of the on-site review, KoldCheck engineers present a
comprehensive report, detailed with useful data and recommendations
for how to solve existing and projected problems cost effectively.
Comprehensive Analysis of Key Data Center Conditions:
> Cooling conditions—A study of existing cooling conditions, such as
rack/cabinet temperatures, measurement of room temperature and
humidification patterns, analysis of room recirculation patterns,
and benchmarking of cooling unit performance against manufacturer
specifications.
> Airflow conditions—Analysis of current airflow conditions,
including perforated tile layout, underflow airflow, perimeter
breaches, and raised-floor bypass area and bypass airflow volume.
> Critical power conditions—An examination of current power
conditions that compares power consumption vs. system capacity,
establishes power distribution limits, quantifies rack utilization.
Redundant capacity of each sub system is determined.
> General room conditions—An overall assessment that surveys the
make-up air system, equipment layout, cabling
management, and room contamination (debris, dust, etc .)
> Infrared (IR) thermal imaging of IT and cooling equipment
Report can include all of the following:
A detailed report is delivered to the client approximately three and
one-half weeks after the analysis is completed.
> Estimate of efficiency improvement with elimination of bypass
airflow (how many cooling units could be turned off or relocated to
eliminate buying additional equipment for future installations)
> Recommendations based on detailed analysis and study of findings
including critical vulnerabilities
> Fixed-price quote for KoldTune to implement KoldCheck
recommendations
> General business case analysis to calculate investment and return
on investment of implementing KoldCheck recommendations
> Calculation of Upsite Coefficient of Effectiveness™
> Tile Flow computational fluid dynamics (CFD) modeling
Additional KoldWorks Services
TileFlow™ CFD Model
Understand airflow with a TileFlow underfloor and above floor
airflow modeling of your data
center. Upsite will develop several TileFlow model scenarios,
including as-found, best case,
new computing equipment, and new cooling equipment.
KoldSeminar
Understand the Dynamics of Your Data Center
Understand the science and issues behind effective data center
cooling with KoldSeminar, a half-day, on-site educational seminar.
The comprehensive session educates key stakeholders from both
Facilities and IT departments. KoldSeminar includes a walkthrough
thermal profile of your data center, a cooling science orientation,
and practical solutions for high density data center cooling issues.
Highlights
> An estimate of data center cooling efficiency/inefficiency and
redundant capacity
> A walkthrough of your data center to estimate relevant measures of
cooling health
> The identification of horizontal and vertical hotspot zones
> A survey of computer room layout comparisons to industry
recommendations and best practices
> A cooling orientation that examines computer room environmental
issues, precision cooling, control of bypass airflow, contamination,
Cold and Hot Aisle arrangements, cooling unit placement, and the
science of optimum cooling system operation
> Discussion of practical solutions for high-density data center
cooling issues
> Infrared (IR) thermal imaging of IT and cooling equipment
Practical Solutions for High-Density Data Center Cooling Issues and
Controlling Bypass Airflow
> Quantify potential financial and operational impact of bypass
airflow, hotspots, and electrostatic discharge (ESD)
> Review of available sealing methods to deal with bypass airflow,
hotspots and ESD, including a hands-on demonstration of how to
install standard products such as Integral, Surface, or Extended
models to seal existing openings
> Review examples and case studies, including financial benefits
from sealing bypass airflow as well as environmental improvements
About Data Clean Asia
Data Clean, one of the oldest and most experienced controlled
environment cleaning and remediation specialists, offers a
comprehensive system of services and products designed to keep
computer rooms running at peak performance. Data Clean has been
helping administrators avoid the high cost of contamination since
1979.
In addition to scheduled cleaning activities, Data Clean offers
24-Hour Facility Restoration Service, Construction site
preparation, Construction maintenance cleaning, and Construction
final cleaning. Data Clean also provides Environmental Services such
as Power Quality Analysis, High Frequency and Radiated Frequency
Monitoring, Air-conditioning / Air-flow analysis and Indoor Air
Quality Services. Data Cleans’ products include KoldLok raised floor
grommets, HotLok blanking panels, PlenaForm and PlenaFill products,
high volume perforated floor tiles, AirBoost underfloor fan
assemblies and other cooling solutions for data centers.
Data Clean Asia is headquartered in Singapore and has offices and
partners throughout the Asia region. For more information contact
Data Clean Asia in Singapore at (65) 6729-1615 or visit their
website at
www.datacleanasia.com.environmental
About Upsite Technologies,
Inc.
Upsite Technologies, Inc.® develops energy-efficient,
high-availability solutions specifically designed to optimize your
data center’s critical physical infrastructure and ensure site
uptime, reliability, and flexibility.
As the innovator of engineered sealing solutions, Upsite continues
to research and develop products and services to
complement and enhance the already extensive lines of patented
KoldLok® products and KoldWorksSM services. Our
inventions optimize thermal load capacity, target hotspot
remediation, reduce intermittent equipment failures, improve
equipment reliability, minimize bypass airflow, and diminish capital
costs associated with installing additional cooling equipment.
Upsite’s well-engineered solutions are employed by data centers
worldwide to help reduce their carbon footprint and
minimize energy and operating costs. Upsite’s products and services
currently optimize more than 6 million ft2 of data
center space.

Insufficient underfloor
pressure enables recirculation of hot air at the top
of the racks, which risks data center reliability.

Proper Cold Aisle/Hot Aisle
configurations with sufficient underfloor
pressure and minimal bypass air will maximize the room’s cooling
efficiency.
|