CONSULTING
 
KOLDWORKS
Electromagnetic Fields
Radiated Frequency Interference
High Frequency Interference
Grounding Studies & Enhancement
Ground Resistant Testing
Signal Reference Grounding
Power Quality Monitoring
Load Balance Measurements
Energy Studies

Air-Conditioning & Flow Analysis
Cooling System Evaluation



















































































































 




Increase Data Center Reliability by Optimizing Your Existing Cooling Infrastructure
KoldWorks is a suite of specialized engineering and educational services designed by Upsite Technologies® to enhance data center performance without additional capital investment.

> Boost data center reliability
> Optimize your current cooling infrastructure
> Enable precision cooling to reduce or eliminate hotspots
> Dramatically reduce bypass airflow
> Assist with data center ASHRAE compliance
> Learn the dynamics of your data center, including cooling requirements, deficiencies,
and the science behind efficient operation

Comprehensive Diagnostic and Remediation Computer Room Services
As data center rack densities increase and thermal loads rise, many organizations resort to increasing the number of cooling units. While this may appear to solve the problem, the added cooling capacity does not offer precision cooling, which will help curb costs and improve energy efficiency.

To achieve cooling efficiency and optimize your capacity, you must eliminate the loss
of chilled air through unsealed cable openings, as well as examine other data center
performance factors, including the location of perforated tiles, relative humidity,
underfloor plenum airflow, computer-room layout, set points and power consumption.

With a range of services, you will be able to meet your technical and budgetary requirements.


Inadequate supply air volume creates an environment in which equipment at the top
of cabinets is significantly hotter. In this photograph, recirculation is evident over
the top of the cabinet, around the ends of rows, and within the cabinet itself.

KOLDPROFILE
Upsite KoldProfile, one of the KoldWorks suite of service offerings, is a survey of your data center cooling to determine the three measurements of data center cooling health based on published standards from ASHRAE and the
Uptime Institute:

> Data Center Hotspots—Temperature and Relative Humidity
> Bypass Airflow—To regain lost conditioned airflow
> Cooling Margin Available—To cool additional equipment

This service takes approximately 1-2 hours depending on data center size and includes the following
activities:

> Count & size raised floor openings to estimate the percentage of bypass airflow
> Measure cabinet air intake temperatures to determine the presence of hotspots
> Measure relative humidity of any identified hotspots
> Sum cooling unit rated cooling capacity and convert from tons to kilo watts (kW)
> Sum cooling unit rated airflow in CFM (cubic feet per minute)
> Sum computing equipment power load in kW
> Determine the presence of latent cooling and its associated Latent Cooling Penalty

After the survey on the data center floor, you will receive:

> On site verbal discussion of findings and recommendations
> Written KoldProfile report detailing findings and recommendations

KoldProfile is necessary for data centers dedicated to improving IT equipment reliability and optimizing critical physical
infrastructure. Learn how capital costs associated with installing additional cooling equipment and operating costs can bereduced, and determine redundant cooling capacity for a high heat density computing equipment installation.


KOLDCHECK
Diagnose Key Data Center Conditions
Examine your data center infrastructure and find out how to regain control of the cooling environment with KoldCheck diagnostic services. Based on what you require, KoldCheck data center experts benchmark your existing conditions and evaluate your computer room to determine ways to optimize your existing cooling investment.

Upon completion of the on-site review, KoldCheck engineers present a comprehensive report, detailed with useful data and recommendations for how to solve existing and projected problems cost effectively.

Comprehensive Analysis of Key Data Center Conditions:
> Cooling conditions—A study of existing cooling conditions, such as rack/cabinet temperatures, measurement of room temperature and humidification patterns, analysis of room recirculation patterns, and benchmarking of cooling unit performance against manufacturer specifications.
> Airflow conditions—Analysis of current airflow conditions, including perforated tile layout, underflow airflow, perimeter breaches, and raised-floor bypass area and bypass airflow volume.
> Critical power conditions—An examination of current power conditions that compares power consumption vs. system capacity, establishes power distribution limits, quantifies rack utilization. Redundant capacity of each sub system is determined.
> General room conditions—An overall assessment that surveys the make-up air system, equipment layout, cabling
management, and room contamination (debris, dust, etc .)
> Infrared (IR) thermal imaging of IT and cooling equipment


Report can include all of the following:
A detailed report is delivered to the client approximately three and one-half weeks after the analysis is completed.
> Estimate of efficiency improvement with elimination of bypass airflow (how many cooling units could be turned off or relocated to eliminate buying additional equipment for future installations)
> Recommendations based on detailed analysis and study of findings including critical vulnerabilities
> Fixed-price quote for KoldTune to implement KoldCheck recommendations
> General business case analysis to calculate investment and return on investment of implementing KoldCheck recommendations
> Calculation of Upsite Coefficient of Effectiveness™
> Tile Flow computational fluid dynamics (CFD) modeling


Additional KoldWorks Services

TileFlow™ CFD Model
Understand airflow with a TileFlow underfloor and above floor airflow modeling of your data
center. Upsite will develop several TileFlow model scenarios, including as-found, best case,
new computing equipment, and new cooling equipment.

KoldSeminar
Understand the Dynamics of Your Data Center
Understand the science and issues behind effective data center cooling with KoldSeminar, a half-day, on-site educational seminar. The comprehensive session educates key stakeholders from both Facilities and IT departments. KoldSeminar includes a walkthrough thermal profile of your data center, a cooling science orientation, and practical solutions for high density data center cooling issues.

Highlights
> An estimate of data center cooling efficiency/inefficiency and redundant capacity
> A walkthrough of your data center to estimate relevant measures of cooling health
> The identification of horizontal and vertical hotspot zones
> A survey of computer room layout comparisons to industry recommendations and best practices
> A cooling orientation that examines computer room environmental issues, precision cooling, control of bypass airflow, contamination, Cold and Hot Aisle arrangements, cooling unit placement, and the science of optimum cooling system operation
> Discussion of practical solutions for high-density data center cooling issues
> Infrared (IR) thermal imaging of IT and cooling equipment Practical Solutions for High-Density Data Center Cooling Issues and Controlling Bypass Airflow
> Quantify potential financial and operational impact of bypass airflow, hotspots, and electrostatic discharge (ESD)
> Review of available sealing methods to deal with bypass airflow, hotspots and ESD, including a hands-on demonstration of how to install standard products such as Integral, Surface, or Extended models to seal existing openings
> Review examples and case studies, including financial benefits from sealing bypass airflow as well as environmental improvements

About Data Clean Asia
Data Clean, one of the oldest and most experienced controlled environment cleaning and remediation specialists, offers a comprehensive system of services and products designed to keep computer rooms running at peak performance. Data Clean has been helping administrators avoid the high cost of contamination since 1979.
In addition to scheduled cleaning activities, Data Clean offers 24-Hour Facility Restoration Service, Construction site
preparation, Construction maintenance cleaning, and Construction final cleaning. Data Clean also provides Environmental Services such as Power Quality Analysis, High Frequency and Radiated Frequency Monitoring, Air-conditioning / Air-flow analysis and Indoor Air Quality Services. Data Cleans’ products include KoldLok raised floor grommets, HotLok blanking panels, PlenaForm and PlenaFill products, high volume perforated floor tiles, AirBoost underfloor fan assemblies and other cooling solutions for data centers.

Data Clean Asia is headquartered in Singapore and has offices and partners throughout the Asia region. For more information contact Data Clean Asia in Singapore at (65) 6729-1615 or visit their website at www.datacleanasia.com.environmental


About Upsite Technologies, Inc.
Upsite Technologies, Inc.® develops energy-efficient, high-availability solutions specifically designed to optimize your data center’s critical physical infrastructure and ensure site uptime, reliability, and flexibility.

As the innovator of engineered sealing solutions, Upsite continues to research and develop products and services to
complement and enhance the already extensive lines of patented KoldLok® products and KoldWorksSM services. Our
inventions optimize thermal load capacity, target hotspot remediation, reduce intermittent equipment failures, improve equipment reliability, minimize bypass airflow, and diminish capital costs associated with installing additional cooling equipment.

Upsite’s well-engineered solutions are employed by data centers worldwide to help reduce their carbon footprint and
minimize energy and operating costs. Upsite’s products and services currently optimize more than 6 million ft2 of data
center space.


Insufficient underfloor pressure enables recirculation of hot air at the top
of the racks, which risks data center reliability.


Proper Cold Aisle/Hot Aisle configurations with sufficient underfloor
pressure and minimal bypass air will maximize the room’s cooling efficiency.
 